VA627 SMS Power Supply – Large Metal Enclosure

Designed specifically for the Vanderbilt Industries SMS Access Control System (formerly known as “The Geoffrey System”) the VA627 provides both 12VDC and 24VDC outputs and can accomodate up to 9 Vanderbilt Industries VRINX, VSRC and VIONX-8 Circuit Boards.
Housed in a white painted steel wall-mount enclosures, the VA627 houses a number of useful features for system builders who wish to have control over their power supply. title=
6 dedicated lock outputs provide 12VDC at 1A for each lock circuit.  Each one can be selected via jumper-link for control via a global lock-disable input if required (see description below).
6 dedicated PCB outputs provide 12VDC at 0.5A for each door control PCB or I/O PCB.
2 dedicated 24VDC outputs provide 0.5A each for an SMS VSRC controller PCB.
Low Voltage DC Power Outputs
6 x fused Lock Outputs 12VDC 1A
6 x PPTC resettable fused (“Polyfuse”) PCB outputs 12VDC 0.5A
2 x PPTC resettable fused (“Polyfuse”) PCB outputs 24VDC 0.5A
9 x PCB Mountings (suitable for VRINX, VSRC and VIONX-8 Circuit Boards)
Monitoring Outputs
1 x Dry Contact (SPDT) monitor output for Battery Low Voltage
1 x Dry Contact (SPDT) monitor output for Mains Failure
The monitoring outputs are intended for connection to system inputs.  The Mains Failure output indicates when the AC mains input has failed (the PSU can still function if back-up batteries are installed).  The Battery Low Voltage output indicates when the battery voltage falls below approximately 10.7 VDC.
Inputs
1 x wet lock-disable input (12VDC or 24VDC) for disabling the 12VDC lock outputs
1 x wet input (12-24VDC) for complete PSU output shutdown
These inputs are intended for interfacing with other systems.  The Lock disable input is primarily intended for receiving a voltage from a fire alarm panel to disable the lock outputs thus allowing the locks to unlock aiding personnel evacuation.  The Output Shutdown input is intended for remote shutdown of the power supply to effect a system hardware reset if needed.
Tamper Switch
Mechanical single-pole tamper switch for direct connection to PCB input.
Battery Back-Up
Space is provided for 2 x 7Ah Sealed Lead-Acid (SLA) batteries independently wired.  The VA627 uses a 35W DC/DC converter to maintain the 24VDC output whilst running on the batteries.  When battery voltage has dropped to approximately 9.8 VDC the VA627 will shut down to prevent battery damage caused by deep discharge.
General Specifications
  • Dimensions (W x H x D): 457mm x 695mm x 120mm
  • Colour: White
  • Removeable lockable lid (two keys supplied)
  • Internal mountings for 9 Vanderbilt Industries VRINX, VSRC and VIONX-8 Circuit Boards
  • Input Voltage: 230-240 VAC
  • Battery Charging Circuit for 2 x 7Ah SLA batteries
  • Approximate Weight: 12.7Kg